The MX2001 water level sensor is used with the HOBO Bluetooth water level data logger (MX2001) and with the HOBO MicroRX Water Level Stations (RX2103 and RX2104) for accurate water pressure, temperature, and water level measurements. These sensors are available in four depth ranges, in stainless steel or titanium (recommended for use in saltwater).
Highlighted Features
- Non-vented design reduces maintenance
- Durable, ceramic sensor
- 3-point NIST-traceable calibration certificate
In what environment does this sensor operate?
This sensor operates in an underwater environment.
What measurements does this sensor support?
The MX2001-S sensor supports the following measurements: Barometric Pressure, Water Level and Water Temperature
MX2001 | RX2103/4 | RX3000 | |
---|---|---|---|
Communications | Bluetooth Low Energy | Cellular | Ethernet, WiFi, Cellular |
Logger Dimensions | 2.54 cm (1.0 in.) diameter, 28.9 cm (11.4 in.) length |
19.95 x 13.68 x 7.49 cm (7.85 x 5.39 x 2.95 in.) |
18.6 x 18.1 x 11.8 cm (7.3 x 7.1 x 4.7 in.) |
Smart Sensor Ports | - | 5 | 10 |
Module Ports | None | 2* | |
On-Board Barometric Sensor | Yes | With required Water Level Module (RXMOD-W1) | |
Water Level Sensor (MX2001-S/-Ti) |
Included | Purchased separately | |
Cable Price | $70 + $4/m | ||
Logger Price | $595
Includes Water Level Sensor
|
Starting at $640/$700
Needs Water Level Sensor
|
Starting at $899**
Needs Water Level Sensor & Module
|
* The RX3000 can only include one Water Level Module/Sensor combination. If your application requires multiple water level sensors, an Analog Module and third party water level sensors with 4-20 mA output are required.
** Further accessories required for monitoring water level
Tilleggsinformasjon
Måleparameter | |
---|---|
Miljø |
Specifications
Pressure (Absolute) And Water Level Measurements MX2001-01-S and MX2001-01-Ti-S:
Operation Range | 0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude |
Factory Calibrated Range | 69 to 207 kPa (10 to 30 psia), 0° to 40°C (32° to 104°F) |
Burst Pressure | 310 kPa (45 psia) or 18 m (60 ft) depth |
Water Level Accuracy* | Typical error: ±0.05% FS, 0.5 cm (0.015 ft) water Maximum error: ±0.1% FS, 1.0 cm (0.03 ft) water |
Raw Pressure Accuracy** | ±0.3% FS, 0.62 kPa (0.09 psi) maximum error |
Resolution | <0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water |
Pressure Response Time (90%)*** | <1 second at a stable temperature |