The HOBO UX100-003 Temperature/Relative Humidity data logger records temperature and relative humidity (within 3.5% accuracy) in indoor environments with its integrated sensors. The data logger is ideal for monitoring occupant comfort in office buildings, tracking food storage conditions in warehouses, logging temperature trends in server rooms, and measuring humidity levels in museums.

Highlighted Features

  • Easy-to view LCD display
  • Large memory capacity
  • Visual high & low alarm thresholds
  • New Burst and Statistics logging modes
  • User-replaceable Relative Humidity sensor
  • Compatible with HOBOware and HOBOware Pro software for logger setup, graphing and analysis

Tilleggsinformasjon

Miljø

Måleparameter

, ,

Spesifikasjoner

Temperature Sensor


Range: -20° to 70°C (-4° to 158°F)
Accuracy: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F)
Resolution: 0.024°C at 25°C (0.04°F at 77°F)
Response time: 4 minutes in air moving 1 m/s (2.2 mph)
Drift: <0.1°C (0.18°F) per year

RH Sensor


Range: 15% to 95% (non-condensing)
Accuracy:
±3.5% from 25% to 85% including hysteresis at 25°C (77°F); below 25% and above 85% ±5% typical
Resolution: 0.07% at 25°C (77°F) and 30% RH
Response time: 43 seconds to 90% in airflow of 1 m/s (2.2 mph)
Drift: <1% per year typical

Logger


Logger Operating Range
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification

Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging modes: Normal, Burst or Statistics
Memory modes: Wrap when Full or Stop when Full
Start modes: Immediately, Push Button, Date & Time or Next Interval
Stop modes: When Memory Full, Push Button, or Date & Time
Restart mode: Push Button
Time accuracy: ±1 minute per month at 25°C (77°F)
Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater
Battery type: One 3V CR2032 lithium battery
Memory: 128 KB (84,650 measurements, maximum)
Download type: USB 2.0 interface
Full memory download time: 20 seconds
LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 3.66 x 8.48 x 1.52 cm (1.44 x 3.34 x 0.6 in.)
Weight: 30 g (1.06 oz)
Environmental rating: IP50

Description: ce – The CE Marking identifies this product as complying with all relevant directives in the European Union (EU)